Cold-formed steel slide-type deflection clip for attaching exterior curtain-wall studs to structural supports while accommodating vertical building movement. Manufactured from galvanized steel in accordance with ASTM A653 and designed for use with cold-formed steel framing systems compliant with AISI S100 and applicable IBC deflection and drift requirements.
Cold-rolled welded wire lath with integral hat channel furring and flattened longitudinal wires for uniform plaster embedment and reinforcement in stucco and plaster assemblies. Manufactured from galvanized steel complying with ASTM A653 and ASTM C847, and intended for installation in accordance with ASTM C1063 and applicable IBC requirements for lath and plaster systems.
applications
Limitations
warranty
10 Year Limited Warranty
-
StructaLath III
ClarkDietrich
Division
true
-
054000
05-4000
05-4000.
05 40 00
05-40-00-
Cold-Formed Metal Framing
Pre-notched galvanized steel spacer and bridging bar for alignment and lateral bracing of cold-formed steel studs in exterior curtain wall framing, loadbearing walls, and high interior partitions. Manufactured from 16-gauge or 18-gauge steel complying with ASTM A653 and intended for use in cold-formed steel framing systems designed in accordance with AISI S100 and applicable IBC structural requirements.
Three-dimensional polymeric rainscreen drainage mat for use behind exterior cladding and stucco wall assemblies to provide a capillary break, drainage path, and ventilation cavity. Intended for installation in accordance with manufacturer instructions and applicable IBC requirements for moisture management in exterior wall systems, including assemblies evaluated for drainage and drying performance.
applications
Use in stucco, stone veneer, brick, or under various siding installations to provide an effective method for drainage and ventilation in the wall system.
Engineered expanded metal lath for stucco applications requiring increased reinforcement over wood or cold-formed steel framing. Manufactured to comply with ASTM C847, suitable as an alternative where 2.5 lb/yd² or 3.4 lb/yd² metal lath is specified, and permitted for installation at 24 inches o.c. over open framing in accordance with ASTM C1063 and applicable IBC requirements.
applications
Self-furring welded wire that provides heavy-duty reinforcing for both stucco and stone installation.
Fire-rated cold-formed steel deflection track system for head-of-wall joints, eliminating the need for castle cuts and field-applied sealant. UL tested in accordance with UL 2079 (5th Edition) and listed under HW-D-1125 and HW-D-0823, suitable for use in fire-resistive wall assemblies complying with applicable IBC joint fire-resistance and movement requirements.
applications
Head-of-wall and head-of-roof deflection joints in fire-resistive gypsum wall assemblies where vertical movement between the floor or roof structure and wall framing is required. Suitable for use with 5/8-inch or 1-1/4-inch gypsum board wall cladding strips installed flush to concrete slabs or fluted decks, allowing independent movement of the structure and wall assembly in accordance with UL-listed details and applicable IBC joint movement requirements.
Limitations
warranty
-
BlazeFrame® RipTrak
ClarkDietrich
Division
true
-
054000
05-4000
05-4000.
05 40 00
05-40-00-
Cold-Formed Metal Framing
Two-piece cold-formed steel drift rail system consisting of a C-shaped rail and interchangeable drift rail clips for attaching exterior curtain-wall studs to structure with either deflection or rigid conditions. Manufactured from galvanized steel complying with ASTM A653, designed to accommodate up to 3 inches of vertical movement and lateral movement when detailed for deflection, or fixed attachment when required, in accordance with AISI S100 and applicable IBC deflection and drift provisions.
Welded wire lath system incorporating 3/8-inch V-shaped trusses with integrated perforated kraft paper backing for interior wall and ceiling plaster assemblies. Manufactured from galvanized steel complying with ASTM C847 and ASTM A653, and intended for installation in accordance with ASTM C1063 and applicable IBC requirements for lath and plaster construction.
applications
V Truss for Walls & Ceilings is designed to improve the performance of stucco on overhead surfaces.
Limitations
warranty
10 Year Limited Warranty
-
V-Truss for Walls & Ceilings
ClarkDietrich
Division
Heavy-gauge steel barrier mesh for installation on wood or cold-formed steel framing to provide resistance to forced penetration in wall, ceiling, or floor assemblies, with or without gypsum sheathing. Manufactured from galvanized steel complying with ASTM A653, compatible with framing designed in accordance with AISI S100, and intended for use in assemblies detailed to meet applicable IBC structural and security requirements.
Cold-formed steel drywall stud and track framing system with enhanced edge stiffening for non-loadbearing interior partitions. Manufactured from galvanized steel complying with ASTM A653 and designed in accordance with AISI S100, with assemblies evaluated for structural, fire-resistance, and acoustical performance to meet applicable IBC requirements.
applications
Limitations
warranty
-
ProSTUD® Drywall Framing System
ClarkDietrich
Division
Cold-formed steel pony wall framing assembly intended to provide out-of-plane structural support for cantilevered partial-height wall systems without top-track bracing.
Cold-formed steel shaftwall framing system consisting of C-T studs and J-Track for fire-resistive shaft enclosures, tested in multiple wall assemblies with a range of gypsum board and shaft liner products. Manufactured from galvanized steel complying with ASTM A653, designed in accordance with AISI S100, and suitable for use in UL-listed assemblies meeting applicable IBC fire-resistance requirements.
applications
Interior non-loadbearing fire-resistive wall assemblies for stair enclosures, elevator shafts, stairwells, vertical chases, and mechanical or service enclosures, including stairwalls finished on both sides with a single layer of 1/2-inch fire-resistance–rated gypsum board. Suitable where rated separation and continuity of fire-resistive protection are required in accordance with applicable IBC provisions.
Limitations
warranty
-
ClarkDietrich Shaftwall System
ClarkDietrich
Division
true
-
070543
07-0543
07-0543.
07 05 43
07-05-43-
Cladding Support Systems
Exterior wall cladding support system consisting of cold-formed steel girts installed over continuous insulation and attached to structure using a self-sealing mechanical fastening assembly.
applications
Rainscreen framing for exterior wall assemblies installed over continuous insulation, providing support for exterior cladding systems while maintaining a ventilated cavity. Suitable for use in drained and ventilated rainscreen wall constructions where minimized thermal bridging and controlled moisture management are required in accordance with applicable IBC provisions.
Limitations
warranty
-
ProChannel Ci™ Cladding Support System
ClarkDietrich
Division
true
-
054000
05-4000
05-4000.
05 40 00
05-40-00-
Cold-Formed Metal Framing
Cold-formed steel framing clip with stiffened corners for rigid structural connections subject to shear, tension, and combined two-axis loading.
applications
Rigid attachment and support of cold-formed steel framing members in wall, floor, and ceiling assemblies, including connections subject to shear, tension, or combined loading.
Limitations
warranty
-
Uni-Clip End Clip (UCEC)
ClarkDietrich
Division
true
-
054000
05-4000
05-4000.
05 40 00
05-40-00-
Cold-Formed Metal Framing
Cold-formed steel deflection track system permitting wall studs to move vertically within the track legs to accommodate live-load movement of the primary structure, and designed to prevent transfer of axial loads to non-loadbearing wall studs.
Pre-notched cold-formed steel bridging and spacing bar for alignment and lateral bracing of interior non-loadbearing, nonstructural stud framing. Manufactured from 33 mil (20 gauge) galvanized steel complying with ASTM A653, configured for 16-inch or 24-inch on-center spacing, and intended for use in cold-formed steel framing systems designed in accordance with AISI S100 and applicable IBC requirements.
The BlazeFrame RipTRAK is the only UL tested fire-rated head of wall joint system that offers an alternate listing by eliminating castle cuts and sealant. Meets UL 2079, 5th edition; HW-D-1125 and HW-D-0823.
applications
Head-of-wall and head-of-roof deflection joints in fire-resistive gypsum wall assemblies accommodating vertical movement between structure and wall framing, for use with 5/8-inch or 1-1/4-inch gypsum board cladding strips at slabs or fluted decks in accordance with UL-listed details and applicable IBC requirements.
Cold-formed steel stud and track framing system with an interlocking, telescoping adjustment component to accommodate slab elevation and minor floor-to-floor height variances. Manufactured from galvanized steel complying with ASTM A653, designed in accordance with AISI S100, and intended for use in wall framing assemblies where adjustable stud length is required under applicable IBC provisions.
applications
Use in interior or exterior cold-formed steel wall framing assemblies where adjustable stud or track members are specified to accommodate slab or floor-to-floor dimensional tolerances. Availability of specific TRAKLOC components may vary by region; verify product selection and suitability for the project location prior to specification.
Limitations
Not all TRAKLOC products are available in all markets. Please check with your local ClarkDietrich sales representative for availability in your area.
warranty
-
TRAKLOC® Drywall Framing System
ClarkDietrich
Division
Fire-rated head-of-wall joint system providing up to 1 inch of movement with UL 2079 Class II or III movement capability, incorporating dual-leg steel profiles to support free-floating studs in UL-listed assemblies. Includes 2 mm cured intumescent material adhered to metal profiles to provide air and smoke sealing, expanding when exposed to temperatures above 375°F to limit heat and flame passage in accordance with applicable IBC joint fire-resistance requirements.
applications
Fire-rated head-of-wall deflection joints in gypsum wall assemblies requiring dual-sided firestopping and support for free-floating studs. Suitable for use as a composite firestop deflection track system in UL-listed fire-resistive wall assemblies where vertical movement and joint fire-resistance are required in accordance with applicable IBC provisions.
Limitations
warranty
-
BlazeFrame® (DL 2) Deep Leg
ClarkDietrich
Division
Fire-rated head-of-wall joint system providing up to 1 inch of movement with UL 2079 Class II or III movement capability, featuring slotted steel legs at 1 inch on center for positive attachment of studs in accordance with UL-listed assemblies. Includes 2 mm cured intumescent material bonded to metal profiles to provide air and smoke sealing, expanding when exposed to temperatures above 375°F to restrict heat and flame passage in compliance with applicable IBC joint fire-resistance requirements.
applications
Composite firestop and framing system for fire-resistive joint conditions at intersections of fire-resistance–rated walls with floor/ceiling or roof/ceiling assemblies. Suitable for use where movement accommodation and joint fire-resistance are required in accordance with UL-listed systems and applicable IBC provisions.
Limitations
warranty
-
BlazeFrame® (DSL 2) Deep Leg
ClarkDietrich
Division
Resilient sound isolation clip for use with 18 mil (25 gauge), 7/8-inch deep drywall furring channel to attach gypsum board while providing mechanical decoupling for acoustical separation in wall and floor-to-ceiling assemblies. Manufactured from galvanized steel complying with ASTM A653 and intended for use in assemblies evaluated in accordance with ASTM E90 and ASTM E413 to meet applicable IBC acoustical performance requirements.
Cold-formed steel backing plate with integral hinged attachment for installation at stud framing to provide shear and pullout resistance for heavy wall-mounted loads. Manufactured from galvanized steel complying with ASTM A653 and intended for use in cold-formed steel framing systems designed in accordance with AISI S100 and applicable IBC structural support requirements.
applications
Provision of continuous wood backing at cold-formed steel stud framing for attachment of wall-mounted fixtures and equipment. Suitable for use with fire-retardant treated wood backing where required by code, including installations incorporating D-Blaze® or FlamePRO® FRT materials in accordance with applicable IBC fire and framing provisions.
Limitations
warranty
-
Danback® Flexible Wood Backing System
ClarkDietrich
Division
Integral liquid waterproofing admixture for watertight concrete, formulated to reduce permeability and limit water migration through hardened concrete. Complies with ASTM C494 Type S, meets CRD C48-92 and DIN 1048 water penetration criteria, conforms to ACI 212.3R-10 requirements for PRAN and PRAH, and is NSF 61 and NSF 372 certified, HPD (Health Product Declaration) declared, EPD (Environmental Product Declaration) published, and compatible with air-entrained concrete.
applications
Use in cast-in-place and precast concrete requiring reduced permeability and resistance to water migration, including elevator pits, retaining walls, foundations, footings, and other below-grade structures. Suitable for water-retaining structures such as swimming pools and cisterns, as well as civil engineering and infrastructure applications where watertight concrete is required.
Resilient channel for attachment of gypsum board to wood or cold-formed steel framing to reduce sound transmission in partition assemblies. Manufactured from galvanized steel complying with ASTM A653 and intended for use in assemblies evaluated in accordance with ASTM E90 and ASTM E413 to meet applicable IBC acoustical performance requirements.
Cold-formed steel anchor clips for attachment of knee walls, light-duty shear walls, and trusses to concrete or masonry foundations. Manufactured from galvanized steel complying with ASTM A653 and intended for use in structural connections designed in accordance with AISI S100 and applicable IBC anchorage and load-transfer requirements.