Electrically raised and held, fail safe controlled gravity descent, UL 10D tested, 1, 2, or 3 hour rated, smoke and draft control, fabric curtain. Push button to raise curtain. Available with vision lite.
applications
Elevator hoistway smoke containment system to protect elevator entrances not separated by an elevator lobby. Exposed and concealed head box mounting details with exposed, flush, and inset jamb details.
Limitations
Head box, 7.5 x 7.5 inches. Fire alarm system connection required. Remotely mounted electrical disconnect and control panel provides 24 volt power. Recommended 18 x 18 inch ceiling access panel for motor and control maintenance.
warranty
-
DSI-600 Elevator Smoke Curtain
Door Systems
Division
Electrically raised and held, fail safe controlled gravity descent, UL 10D 1 hour rated, fabric, smoke and draft control curtain. Push to exit button or fabric slot for egress.
applications
Area separation curtain with unlimited width. Exposed and multiple concealed head box mounting details with exposed, flush, and inset jamb details.
Limitations
Head box, 7.5 inches, minimum. Larger boxes may be required for curtains higher than 9'-10".
warranty
-
DSI-C1HR Automatic Fire Protective Smoke Curtain
Door Systems
Division
Accordion-style opening protective fire curtain system, UL 10B–listed for up to four-hour fire-resistance ratings, providing smoke and fire separation for large or irregular openings without columns or corner posts. Fire-rated fiberglass fabric folds into a compact concealed head box with finished bottom tray, creating atrium, stairwell, and escalator smoke and fire barriers that remain virtually invisible until deployment.
applications
Limitations
warranty
83486
8-3486
DSI-A4HR Accordion Fire Protective Curtain
Door Systems
Division 8
Electrically raised, gravity fail-safe deploying, UL 10D 3-hour rated fiberglass fabric smoke and fire curtain with stainless steel wire reinforcement. Compact concealed head box with recessed side guides; controlled gravity descent upon alarm or power loss for continuous opening protection.
applications
Use at large interior openings where a concealed automatic smoke and fire barrier is required to support the building’s life-safety strategy. Typical applications include atriums, corridors, and architecturally significant openings where maintaining clean sightlines and minimizing visual impact are important design considerations. It is suited for projects requiring a three-hour fire protective smoke curtain coordinated with fire alarm and life-safety systems.
Limitations
Not intended to function as a fire-resistance–rated wall or door assembly. It should not be used in applications that require powered deployment in place of gravity fail-safe operation. Opening dimensions must remain within the approved limits for single-barrel or multi-barrel configurations as tested and listed.
warranty
-
DSI-C3HR Automatic Fire Protective Smoke Curtain
Door Systems
Division
Electrically raised and held, fail safe controlled gravity descent, UL 10D tested 3 hour rated, smoke and fire control, fabric curtain.
applications
Area separation curtain for horizontal openings at ceilings, atria, stairs and skylights. Above and under slab mounting with head and tail boxes and side guide rails.
Limitations
Sizes up to 26 feet wide by 33 feet long. Fire alarm system connection required. Remotely mounted electrical disconnect and control panel provides 24 volt power.
warranty
083489
08-3489
DSI-H3HR Horizontal Fire Protective Smoke Curtain
Door Systems
Division 08
Electrically raised and held, fail safe controlled gravity descent to operational height, UL 10D tested, 1 hour rated smoke and fire control fabric curtain. Optional 3 hour rating.
applications
Protect stair and escalator floor openings and atria to provide smoke containment and create smoke compartments. Exposed and multiple concealed head box mounting details. Unlimited width and height.
Limitations
Single barrel up to 16 feet wide openings. Multi-barrel for wider openings. Fire alarm system connection required. Remotely mounted electrical disconnect and control panel provides 24 volt power.
warranty
-
DSI-D1HR Automatic Draft Curtain
Door Systems
Division
Fusible link held, fail safe controlled gravity descent, UL 10D tested with 1 or 3 hour, smoke and fire control fabric curtain.
applications
Protect openings in fire rated walls not requiring egress. Exposed and concealed head box mounting details with exposed, flush, and inset jamb details.
Limitations
Head box height 7 inches minimum. Manual reset ager deployment.
warranty
083486
08-3486
DSI-M10D Manual Fire Protective Smoke Curtain
Door Systems
Division 08
AGC Pyrobel® by McGrory Glass is a barrier-to-heat product that protects against radiant and conductive heat transfer. Fire-rating of up to 45, 60, 90 or 120 minutes. Clear, low-iron glazing. Cradle to Cradle Certified™ Silver
• Environmental Product Declaration (EPD) available. Red List free
applications
For use in doors, sidelites, transoms, borrowed lites, and wall applications. Interior and exterior use.
PYRAN® Platinum Fire-Protective Glass is a fire-protection-rated glass-ceramic glazing material with a thickness of approximately 3/16″ (5 mm)with a transparent appearance For use in non-impact, non-safety rated locations such as transoms and windows. Largest sheet size available in the industry at 51″ x 99″. Transparent and wireless.
applications
Limitations
warranty
088800
08-8800
SCHOTT Pyran Platinum® F by McGrory Glass
McGrory Glass
Division 08
SCHOTT PYRAN® L Platinum Fire-Rated Glass is a fire-protection-rated and impact-safety-rated glazing material with a thickness of approximately 5/16″ (9 mm), transparent and wireless, made from a laminated glass-ceramic with a transparent appearance for use in safety-rated locations such as door lites, sidelites, and windows. Fire-rating up to 90 minutes and up to 180 minutes in doors. Passes positive pressure test standard UL 10C / NFPA 252. Withstands thermal shock. Approved for use with any standard fire-rated frame with same rating. Can be used to construct insulated glazing units. Can be lightly sandblasted or delivered with surface-applied opacity film, without affecting fire rating.
FEVE fluoropolymer powder coating for architectural metal substrates, providing high-performance exterior durability. Meets or exceeds the performance requirements of AAMA 2605.
applications
Used on exterior applications like curtain wall, windows etc.
FEVE fluoropolymer powder coating for architectural metal substrates, formulated for exterior exposure and long-term color and gloss retention. Complies with and exceeds the performance requirements of AAMA 2605 for high-performance organic coatings.
applications
Used on exterior applications like commercial storefront, low rise curtain/window wall, windows etc.
Limitations
High performance Super Durable Polyester powders
Meets and exceeds the performance requirements of AAMA 2604